Description

Book Synopsis
MRI PHYSICS

MRI PHYSICS

TECH TO TECH EXPLANATIONS

Technologists must have a solid understanding of the physics behind Magnetic Resonance Imaging (MRI), including safety, the hows and whys of the quantum physics of the MR phenomenon, and how to competently operate MRI scanners. Generating the highest quality images of the human body involves thorough knowledge of scanner hardware, pulse sequences, image contrast, geometric parameters, and tissue suppression techniques.

MRI Physics: Tech to Tech Explanations is designed to help student MRI technologists and radiotherapists preparing for Advanced MRI certification examinations to better understand difficult concepts and topics in a quick and easy manner.

Written by a highly experienced technologist, this useful guide provides clear and reader-friendly coverage of what every MR Technologist needs to know. Topics include safety considerations associated with the magnetic field and RF, pulse sequences,

Table of Contents

About the Author xv

Preface xvii

Acknowledgements xix

Introduction 1

1 Hardware: Magnet Types and Coils 15

Magnets 15

Coils 17

2 The Basics 23

Why the Hydrogen Molecule? 24

The Net Magnetization Vector 26

MRI is a Sequence of Events 27

Free Induction Decay (FID) 32

Relaxation 33

Proton Density 38

Image Contrast 38

The IQ Triangle: Contrast, SNR, Resolution 39

B0 and B1 43

Free and Bound Protons 44

3 Image Weighting 47

Where Does Image Weighting Come From? 48

Time of Repetition (TR) 50

Time of Echo (TE) 52

TE and TR 54

Why Different TR Ranges for Different Field Strengths? 54

How Does TR Control T1? 55

What Does TR Affect? 56

Interpreting the T1 Relaxation Curve 57

Time of Repetition: Effects of the TR 57

TE: The T1 and T2 of it 58

Interpreting the T2 Relaxation Curve 60

Effects of TE on Image Contrast 62

What Do the Lines on the Curves Really Mean Anyway? 62

One Last Weighting Triangle 65

T1 and T2 Contrast Review 66

4 Introduction to the Basic Pulse Sequences 69

What is a Pulse Sequence? 69

Spin Echo (SE) 70

Gradient Echo/Gradient Recalled Echo (GRE) 73

Line Diagram Anatomy 74

The Ernst Angle 77

5 Multi Echo Spin Echo Sequence 81

Introduction to k-Space 82

k-Space: Phase Encoding 85

With FSE, Watch the Speed Limit! 86

k-Space, ETL, and Image Contrast 87

Filling k-Space 89

Pros and Cons of FSE 89

Another Way to View T2* and 180°s 91

Where Do Relaxation and Decay Curves Come From? 92

A T2* Curve Compared to the T2 Curve 93

Metal Artifact Reduction (MARS) 94

Driven Equilibrium: A “Forced T1” 95

3D FSE: CUBE/SPACE/VISTA 97

Single Shot FSE/HASTE 98

6 Tissue Suppression 105

Tissue Saturation versus Suppression 107

Inversion Recovery – Part One: STIR 108

Inversion Recovery: STIR with Vectors 109

Inversion Recovery Part Two: T2 FLAIR 113

IR Sequences: T1 and T2 FLAIR 116

IR Weightings: STIR, T1 and T2 FLAIR 117

Inversion Recovery – Part Two 119

The Rupture View 120

Tissue Saturation: Chemical Shift 121

Chemical Saturation at Low Fields 123

Tissue Saturation: SPAIR and SPIR 124

The Dixon Technique 126

Water Excitation 126

Saturation Pulses or Bands 129

Subtractions 131

Magnetization Transfer 135

IR Prepped Sequences 137

How is an RF Pulse Selective or Non-Selective? 140

Water Excitation Sequences 142

7 The Gradient Echo Sequence 145

GRE Sequence Structure 147

Phase Dispersion and Gradient Reversal 148

Analog to Digital Converter (ADC) 149

GRE Sequence Image Weighting 149

Two Different Kinds of T2 Relaxation 152

The GRE Weighting Triangle 153

GRE and SE Differences 156

Different Gradient Echo Types 157

In and Out of Phase TEs 161

In Phase/Out of Phase at 1.5 T 163

8 Gradient Echo Magnetic Resonance Angiography 167

Time of Flight MRA 168

TOF Angiography: Two Golden Rules 171

Types of MRA Sequences 171

TOF Concept in MRA versus MRV 172

2D versus 3D 172

2D TOF MRAs 175

3D TOF MRAs 176

In-Plane Saturation 178

In-Plane Saturation Avoidance 179

Magnetization Transfer (MT) 181

Options for Better MRAs 183

Phase Contrast MRA 185

9 k-Space 191

What Is Fourier Transform? 192

k-Space Filling 192

10 Echo Planar Sequences 203

Diffusion Weighted Imaging 205

Diffusion Tensor Imaging or White Matter Tractography 215

Susceptibility Weighted Imaging 216

Brain Perfusion 218

Arterial Spin Labeling 222

Spectroscopy 225

11 Geometric Parameters: Trade-offs and Effects on Image Quality 231

Field of View (FOV) Is Your Film Size 232

Nex, ACQ, NSA, and SNR 235

Scan Matrix 237

Frequency Matrix 237

Echo Train Length 238

Echo Spacing 239

Echo Train Balancing 240

Slice Thickness and Slice Gap 242

Fractional Echo 243

Bandwidth 244

Rectangular (Rec.) FOV 249

No Phase Wrap/Phase Oversampling/Fold-Over Suppression 251

Concatenations or Acquisitions 254

Sequential Order Acquisition 255

12 Image Artifacts 257

Motion 258

Flow Artifact/Phase Mis-registration 262

RF Artifacts 265

Wrap/Aliasing/Fold-over Artifact 265

Gibbs Artifact (Ringing/Truncation) 268

Chemical Shift Artifact 271

Cross-talk 276

Cross-excitation 278

Gradient Warp or Distortion 281

Metal Artifacts 281

Corduroy Artifact 283

Annifact 284

Moiré Fringe Artifact or Zebra Artifact 285

Magnetic Susceptibility Artifact 286

Dielectric Effect or Standing Wave 288

Magic Angle Artifact 290

13 Gradients 295

Physical Gradients 296

Logical Gradients 302

14 MRI Math 313

The Larmor Equation: W0 = γB0 314

Acquisitions or Nex or NSA 314

Scan Time Equations 315

Pixel Size and Voxel Volume 317

How to Convert Hz per Pixel to MHz 318

In and Out of Phase TEs 319

Dixon Method or Technique 320

SNR and the 3D Sequence 321

15 Parallel Imaging 325

Parallel Imaging: What Is It? 325

When and Where to Use the Speed 326

Parallel Imaging: How Does It Work? 327

Parallel Imaging: Pros and Cons 330

16 IV Gadolinium 335

Why We Use Gad 336

How Does Gad Shorten the T1 of Tissues? 337

The Blood–Brain Barrier 341

Post Contrast T2 FLAIR Imaging 342

Imaging Gadolinium 345

Eovist® 347

Glossary 351

Suggested Reading 388

Index 389

MRI Physics

Product form

£38.66

Includes FREE delivery

RRP £42.95 – you save £4.29 (9%)

Order before 4pm today for delivery by Tue 23 Dec 2025.

A Paperback / softback by Stephen J. Powers

15 in stock


    View other formats and editions of MRI Physics by Stephen J. Powers

    Publisher: John Wiley and Sons Ltd
    Publication Date: 01/04/2021
    ISBN13: 9781119615026, 978-1119615026
    ISBN10: 111961502X

    Description

    Book Synopsis
    MRI PHYSICS

    MRI PHYSICS

    TECH TO TECH EXPLANATIONS

    Technologists must have a solid understanding of the physics behind Magnetic Resonance Imaging (MRI), including safety, the hows and whys of the quantum physics of the MR phenomenon, and how to competently operate MRI scanners. Generating the highest quality images of the human body involves thorough knowledge of scanner hardware, pulse sequences, image contrast, geometric parameters, and tissue suppression techniques.

    MRI Physics: Tech to Tech Explanations is designed to help student MRI technologists and radiotherapists preparing for Advanced MRI certification examinations to better understand difficult concepts and topics in a quick and easy manner.

    Written by a highly experienced technologist, this useful guide provides clear and reader-friendly coverage of what every MR Technologist needs to know. Topics include safety considerations associated with the magnetic field and RF, pulse sequences,

    Table of Contents

    About the Author xv

    Preface xvii

    Acknowledgements xix

    Introduction 1

    1 Hardware: Magnet Types and Coils 15

    Magnets 15

    Coils 17

    2 The Basics 23

    Why the Hydrogen Molecule? 24

    The Net Magnetization Vector 26

    MRI is a Sequence of Events 27

    Free Induction Decay (FID) 32

    Relaxation 33

    Proton Density 38

    Image Contrast 38

    The IQ Triangle: Contrast, SNR, Resolution 39

    B0 and B1 43

    Free and Bound Protons 44

    3 Image Weighting 47

    Where Does Image Weighting Come From? 48

    Time of Repetition (TR) 50

    Time of Echo (TE) 52

    TE and TR 54

    Why Different TR Ranges for Different Field Strengths? 54

    How Does TR Control T1? 55

    What Does TR Affect? 56

    Interpreting the T1 Relaxation Curve 57

    Time of Repetition: Effects of the TR 57

    TE: The T1 and T2 of it 58

    Interpreting the T2 Relaxation Curve 60

    Effects of TE on Image Contrast 62

    What Do the Lines on the Curves Really Mean Anyway? 62

    One Last Weighting Triangle 65

    T1 and T2 Contrast Review 66

    4 Introduction to the Basic Pulse Sequences 69

    What is a Pulse Sequence? 69

    Spin Echo (SE) 70

    Gradient Echo/Gradient Recalled Echo (GRE) 73

    Line Diagram Anatomy 74

    The Ernst Angle 77

    5 Multi Echo Spin Echo Sequence 81

    Introduction to k-Space 82

    k-Space: Phase Encoding 85

    With FSE, Watch the Speed Limit! 86

    k-Space, ETL, and Image Contrast 87

    Filling k-Space 89

    Pros and Cons of FSE 89

    Another Way to View T2* and 180°s 91

    Where Do Relaxation and Decay Curves Come From? 92

    A T2* Curve Compared to the T2 Curve 93

    Metal Artifact Reduction (MARS) 94

    Driven Equilibrium: A “Forced T1” 95

    3D FSE: CUBE/SPACE/VISTA 97

    Single Shot FSE/HASTE 98

    6 Tissue Suppression 105

    Tissue Saturation versus Suppression 107

    Inversion Recovery – Part One: STIR 108

    Inversion Recovery: STIR with Vectors 109

    Inversion Recovery Part Two: T2 FLAIR 113

    IR Sequences: T1 and T2 FLAIR 116

    IR Weightings: STIR, T1 and T2 FLAIR 117

    Inversion Recovery – Part Two 119

    The Rupture View 120

    Tissue Saturation: Chemical Shift 121

    Chemical Saturation at Low Fields 123

    Tissue Saturation: SPAIR and SPIR 124

    The Dixon Technique 126

    Water Excitation 126

    Saturation Pulses or Bands 129

    Subtractions 131

    Magnetization Transfer 135

    IR Prepped Sequences 137

    How is an RF Pulse Selective or Non-Selective? 140

    Water Excitation Sequences 142

    7 The Gradient Echo Sequence 145

    GRE Sequence Structure 147

    Phase Dispersion and Gradient Reversal 148

    Analog to Digital Converter (ADC) 149

    GRE Sequence Image Weighting 149

    Two Different Kinds of T2 Relaxation 152

    The GRE Weighting Triangle 153

    GRE and SE Differences 156

    Different Gradient Echo Types 157

    In and Out of Phase TEs 161

    In Phase/Out of Phase at 1.5 T 163

    8 Gradient Echo Magnetic Resonance Angiography 167

    Time of Flight MRA 168

    TOF Angiography: Two Golden Rules 171

    Types of MRA Sequences 171

    TOF Concept in MRA versus MRV 172

    2D versus 3D 172

    2D TOF MRAs 175

    3D TOF MRAs 176

    In-Plane Saturation 178

    In-Plane Saturation Avoidance 179

    Magnetization Transfer (MT) 181

    Options for Better MRAs 183

    Phase Contrast MRA 185

    9 k-Space 191

    What Is Fourier Transform? 192

    k-Space Filling 192

    10 Echo Planar Sequences 203

    Diffusion Weighted Imaging 205

    Diffusion Tensor Imaging or White Matter Tractography 215

    Susceptibility Weighted Imaging 216

    Brain Perfusion 218

    Arterial Spin Labeling 222

    Spectroscopy 225

    11 Geometric Parameters: Trade-offs and Effects on Image Quality 231

    Field of View (FOV) Is Your Film Size 232

    Nex, ACQ, NSA, and SNR 235

    Scan Matrix 237

    Frequency Matrix 237

    Echo Train Length 238

    Echo Spacing 239

    Echo Train Balancing 240

    Slice Thickness and Slice Gap 242

    Fractional Echo 243

    Bandwidth 244

    Rectangular (Rec.) FOV 249

    No Phase Wrap/Phase Oversampling/Fold-Over Suppression 251

    Concatenations or Acquisitions 254

    Sequential Order Acquisition 255

    12 Image Artifacts 257

    Motion 258

    Flow Artifact/Phase Mis-registration 262

    RF Artifacts 265

    Wrap/Aliasing/Fold-over Artifact 265

    Gibbs Artifact (Ringing/Truncation) 268

    Chemical Shift Artifact 271

    Cross-talk 276

    Cross-excitation 278

    Gradient Warp or Distortion 281

    Metal Artifacts 281

    Corduroy Artifact 283

    Annifact 284

    Moiré Fringe Artifact or Zebra Artifact 285

    Magnetic Susceptibility Artifact 286

    Dielectric Effect or Standing Wave 288

    Magic Angle Artifact 290

    13 Gradients 295

    Physical Gradients 296

    Logical Gradients 302

    14 MRI Math 313

    The Larmor Equation: W0 = γB0 314

    Acquisitions or Nex or NSA 314

    Scan Time Equations 315

    Pixel Size and Voxel Volume 317

    How to Convert Hz per Pixel to MHz 318

    In and Out of Phase TEs 319

    Dixon Method or Technique 320

    SNR and the 3D Sequence 321

    15 Parallel Imaging 325

    Parallel Imaging: What Is It? 325

    When and Where to Use the Speed 326

    Parallel Imaging: How Does It Work? 327

    Parallel Imaging: Pros and Cons 330

    16 IV Gadolinium 335

    Why We Use Gad 336

    How Does Gad Shorten the T1 of Tissues? 337

    The Blood–Brain Barrier 341

    Post Contrast T2 FLAIR Imaging 342

    Imaging Gadolinium 345

    Eovist® 347

    Glossary 351

    Suggested Reading 388

    Index 389