Description

Book Synopsis
MRI PHYSICS

MRI PHYSICS

TECH TO TECH EXPLANATIONS

Technologists must have a solid understanding of the physics behind Magnetic Resonance Imaging (MRI), including safety, the hows and whys of the quantum physics of the MR phenomenon, and how to competently operate MRI scanners. Generating the highest quality images of the human body involves thorough knowledge of scanner hardware, pulse sequences, image contrast, geometric parameters, and tissue suppression techniques.

MRI Physics: Tech to Tech Explanations is designed to help student MRI technologists and radiotherapists preparing for Advanced MRI certification examinations to better understand difficult concepts and topics in a quick and easy manner.

Written by a highly experienced technologist, this useful guide provides clear and reader-friendly coverage of what every MR Technologist needs to know. Topics include safety considerations associated with the magnetic field and RF, pulse sequences,

Table of Contents

About the Author xv

Preface xvii

Acknowledgements xix

Introduction 1

1 Hardware: Magnet Types and Coils 15

Magnets 15

Coils 17

2 The Basics 23

Why the Hydrogen Molecule? 24

The Net Magnetization Vector 26

MRI is a Sequence of Events 27

Free Induction Decay (FID) 32

Relaxation 33

Proton Density 38

Image Contrast 38

The IQ Triangle: Contrast, SNR, Resolution 39

B0 and B1 43

Free and Bound Protons 44

3 Image Weighting 47

Where Does Image Weighting Come From? 48

Time of Repetition (TR) 50

Time of Echo (TE) 52

TE and TR 54

Why Different TR Ranges for Different Field Strengths? 54

How Does TR Control T1? 55

What Does TR Affect? 56

Interpreting the T1 Relaxation Curve 57

Time of Repetition: Effects of the TR 57

TE: The T1 and T2 of it 58

Interpreting the T2 Relaxation Curve 60

Effects of TE on Image Contrast 62

What Do the Lines on the Curves Really Mean Anyway? 62

One Last Weighting Triangle 65

T1 and T2 Contrast Review 66

4 Introduction to the Basic Pulse Sequences 69

What is a Pulse Sequence? 69

Spin Echo (SE) 70

Gradient Echo/Gradient Recalled Echo (GRE) 73

Line Diagram Anatomy 74

The Ernst Angle 77

5 Multi Echo Spin Echo Sequence 81

Introduction to k-Space 82

k-Space: Phase Encoding 85

With FSE, Watch the Speed Limit! 86

k-Space, ETL, and Image Contrast 87

Filling k-Space 89

Pros and Cons of FSE 89

Another Way to View T2* and 180°s 91

Where Do Relaxation and Decay Curves Come From? 92

A T2* Curve Compared to the T2 Curve 93

Metal Artifact Reduction (MARS) 94

Driven Equilibrium: A “Forced T1” 95

3D FSE: CUBE/SPACE/VISTA 97

Single Shot FSE/HASTE 98

6 Tissue Suppression 105

Tissue Saturation versus Suppression 107

Inversion Recovery – Part One: STIR 108

Inversion Recovery: STIR with Vectors 109

Inversion Recovery Part Two: T2 FLAIR 113

IR Sequences: T1 and T2 FLAIR 116

IR Weightings: STIR, T1 and T2 FLAIR 117

Inversion Recovery – Part Two 119

The Rupture View 120

Tissue Saturation: Chemical Shift 121

Chemical Saturation at Low Fields 123

Tissue Saturation: SPAIR and SPIR 124

The Dixon Technique 126

Water Excitation 126

Saturation Pulses or Bands 129

Subtractions 131

Magnetization Transfer 135

IR Prepped Sequences 137

How is an RF Pulse Selective or Non-Selective? 140

Water Excitation Sequences 142

7 The Gradient Echo Sequence 145

GRE Sequence Structure 147

Phase Dispersion and Gradient Reversal 148

Analog to Digital Converter (ADC) 149

GRE Sequence Image Weighting 149

Two Different Kinds of T2 Relaxation 152

The GRE Weighting Triangle 153

GRE and SE Differences 156

Different Gradient Echo Types 157

In and Out of Phase TEs 161

In Phase/Out of Phase at 1.5 T 163

8 Gradient Echo Magnetic Resonance Angiography 167

Time of Flight MRA 168

TOF Angiography: Two Golden Rules 171

Types of MRA Sequences 171

TOF Concept in MRA versus MRV 172

2D versus 3D 172

2D TOF MRAs 175

3D TOF MRAs 176

In-Plane Saturation 178

In-Plane Saturation Avoidance 179

Magnetization Transfer (MT) 181

Options for Better MRAs 183

Phase Contrast MRA 185

9 k-Space 191

What Is Fourier Transform? 192

k-Space Filling 192

10 Echo Planar Sequences 203

Diffusion Weighted Imaging 205

Diffusion Tensor Imaging or White Matter Tractography 215

Susceptibility Weighted Imaging 216

Brain Perfusion 218

Arterial Spin Labeling 222

Spectroscopy 225

11 Geometric Parameters: Trade-offs and Effects on Image Quality 231

Field of View (FOV) Is Your Film Size 232

Nex, ACQ, NSA, and SNR 235

Scan Matrix 237

Frequency Matrix 237

Echo Train Length 238

Echo Spacing 239

Echo Train Balancing 240

Slice Thickness and Slice Gap 242

Fractional Echo 243

Bandwidth 244

Rectangular (Rec.) FOV 249

No Phase Wrap/Phase Oversampling/Fold-Over Suppression 251

Concatenations or Acquisitions 254

Sequential Order Acquisition 255

12 Image Artifacts 257

Motion 258

Flow Artifact/Phase Mis-registration 262

RF Artifacts 265

Wrap/Aliasing/Fold-over Artifact 265

Gibbs Artifact (Ringing/Truncation) 268

Chemical Shift Artifact 271

Cross-talk 276

Cross-excitation 278

Gradient Warp or Distortion 281

Metal Artifacts 281

Corduroy Artifact 283

Annifact 284

Moiré Fringe Artifact or Zebra Artifact 285

Magnetic Susceptibility Artifact 286

Dielectric Effect or Standing Wave 288

Magic Angle Artifact 290

13 Gradients 295

Physical Gradients 296

Logical Gradients 302

14 MRI Math 313

The Larmor Equation: W0 = γB0 314

Acquisitions or Nex or NSA 314

Scan Time Equations 315

Pixel Size and Voxel Volume 317

How to Convert Hz per Pixel to MHz 318

In and Out of Phase TEs 319

Dixon Method or Technique 320

SNR and the 3D Sequence 321

15 Parallel Imaging 325

Parallel Imaging: What Is It? 325

When and Where to Use the Speed 326

Parallel Imaging: How Does It Work? 327

Parallel Imaging: Pros and Cons 330

16 IV Gadolinium 335

Why We Use Gad 336

How Does Gad Shorten the T1 of Tissues? 337

The Blood–Brain Barrier 341

Post Contrast T2 FLAIR Imaging 342

Imaging Gadolinium 345

Eovist® 347

Glossary 351

Suggested Reading 388

Index 389

MRI Physics

    Product form

    £40.80

    Includes FREE delivery

    RRP £42.95 – you save £2.15 (5%)

    Order before 4pm tomorrow for delivery by Sat 20 Jun 2026.

    A Paperback / softback by Stephen J. Powers


      View other formats and editions of MRI Physics by Stephen J. Powers

      Publisher: John Wiley and Sons Ltd
      Publication Date: 01/04/2021
      ISBN13: 9781119615026, 978-1119615026
      ISBN10: 111961502X

      Description

      Book Synopsis
      MRI PHYSICS

      MRI PHYSICS

      TECH TO TECH EXPLANATIONS

      Technologists must have a solid understanding of the physics behind Magnetic Resonance Imaging (MRI), including safety, the hows and whys of the quantum physics of the MR phenomenon, and how to competently operate MRI scanners. Generating the highest quality images of the human body involves thorough knowledge of scanner hardware, pulse sequences, image contrast, geometric parameters, and tissue suppression techniques.

      MRI Physics: Tech to Tech Explanations is designed to help student MRI technologists and radiotherapists preparing for Advanced MRI certification examinations to better understand difficult concepts and topics in a quick and easy manner.

      Written by a highly experienced technologist, this useful guide provides clear and reader-friendly coverage of what every MR Technologist needs to know. Topics include safety considerations associated with the magnetic field and RF, pulse sequences,

      Table of Contents

      About the Author xv

      Preface xvii

      Acknowledgements xix

      Introduction 1

      1 Hardware: Magnet Types and Coils 15

      Magnets 15

      Coils 17

      2 The Basics 23

      Why the Hydrogen Molecule? 24

      The Net Magnetization Vector 26

      MRI is a Sequence of Events 27

      Free Induction Decay (FID) 32

      Relaxation 33

      Proton Density 38

      Image Contrast 38

      The IQ Triangle: Contrast, SNR, Resolution 39

      B0 and B1 43

      Free and Bound Protons 44

      3 Image Weighting 47

      Where Does Image Weighting Come From? 48

      Time of Repetition (TR) 50

      Time of Echo (TE) 52

      TE and TR 54

      Why Different TR Ranges for Different Field Strengths? 54

      How Does TR Control T1? 55

      What Does TR Affect? 56

      Interpreting the T1 Relaxation Curve 57

      Time of Repetition: Effects of the TR 57

      TE: The T1 and T2 of it 58

      Interpreting the T2 Relaxation Curve 60

      Effects of TE on Image Contrast 62

      What Do the Lines on the Curves Really Mean Anyway? 62

      One Last Weighting Triangle 65

      T1 and T2 Contrast Review 66

      4 Introduction to the Basic Pulse Sequences 69

      What is a Pulse Sequence? 69

      Spin Echo (SE) 70

      Gradient Echo/Gradient Recalled Echo (GRE) 73

      Line Diagram Anatomy 74

      The Ernst Angle 77

      5 Multi Echo Spin Echo Sequence 81

      Introduction to k-Space 82

      k-Space: Phase Encoding 85

      With FSE, Watch the Speed Limit! 86

      k-Space, ETL, and Image Contrast 87

      Filling k-Space 89

      Pros and Cons of FSE 89

      Another Way to View T2* and 180°s 91

      Where Do Relaxation and Decay Curves Come From? 92

      A T2* Curve Compared to the T2 Curve 93

      Metal Artifact Reduction (MARS) 94

      Driven Equilibrium: A “Forced T1” 95

      3D FSE: CUBE/SPACE/VISTA 97

      Single Shot FSE/HASTE 98

      6 Tissue Suppression 105

      Tissue Saturation versus Suppression 107

      Inversion Recovery – Part One: STIR 108

      Inversion Recovery: STIR with Vectors 109

      Inversion Recovery Part Two: T2 FLAIR 113

      IR Sequences: T1 and T2 FLAIR 116

      IR Weightings: STIR, T1 and T2 FLAIR 117

      Inversion Recovery – Part Two 119

      The Rupture View 120

      Tissue Saturation: Chemical Shift 121

      Chemical Saturation at Low Fields 123

      Tissue Saturation: SPAIR and SPIR 124

      The Dixon Technique 126

      Water Excitation 126

      Saturation Pulses or Bands 129

      Subtractions 131

      Magnetization Transfer 135

      IR Prepped Sequences 137

      How is an RF Pulse Selective or Non-Selective? 140

      Water Excitation Sequences 142

      7 The Gradient Echo Sequence 145

      GRE Sequence Structure 147

      Phase Dispersion and Gradient Reversal 148

      Analog to Digital Converter (ADC) 149

      GRE Sequence Image Weighting 149

      Two Different Kinds of T2 Relaxation 152

      The GRE Weighting Triangle 153

      GRE and SE Differences 156

      Different Gradient Echo Types 157

      In and Out of Phase TEs 161

      In Phase/Out of Phase at 1.5 T 163

      8 Gradient Echo Magnetic Resonance Angiography 167

      Time of Flight MRA 168

      TOF Angiography: Two Golden Rules 171

      Types of MRA Sequences 171

      TOF Concept in MRA versus MRV 172

      2D versus 3D 172

      2D TOF MRAs 175

      3D TOF MRAs 176

      In-Plane Saturation 178

      In-Plane Saturation Avoidance 179

      Magnetization Transfer (MT) 181

      Options for Better MRAs 183

      Phase Contrast MRA 185

      9 k-Space 191

      What Is Fourier Transform? 192

      k-Space Filling 192

      10 Echo Planar Sequences 203

      Diffusion Weighted Imaging 205

      Diffusion Tensor Imaging or White Matter Tractography 215

      Susceptibility Weighted Imaging 216

      Brain Perfusion 218

      Arterial Spin Labeling 222

      Spectroscopy 225

      11 Geometric Parameters: Trade-offs and Effects on Image Quality 231

      Field of View (FOV) Is Your Film Size 232

      Nex, ACQ, NSA, and SNR 235

      Scan Matrix 237

      Frequency Matrix 237

      Echo Train Length 238

      Echo Spacing 239

      Echo Train Balancing 240

      Slice Thickness and Slice Gap 242

      Fractional Echo 243

      Bandwidth 244

      Rectangular (Rec.) FOV 249

      No Phase Wrap/Phase Oversampling/Fold-Over Suppression 251

      Concatenations or Acquisitions 254

      Sequential Order Acquisition 255

      12 Image Artifacts 257

      Motion 258

      Flow Artifact/Phase Mis-registration 262

      RF Artifacts 265

      Wrap/Aliasing/Fold-over Artifact 265

      Gibbs Artifact (Ringing/Truncation) 268

      Chemical Shift Artifact 271

      Cross-talk 276

      Cross-excitation 278

      Gradient Warp or Distortion 281

      Metal Artifacts 281

      Corduroy Artifact 283

      Annifact 284

      Moiré Fringe Artifact or Zebra Artifact 285

      Magnetic Susceptibility Artifact 286

      Dielectric Effect or Standing Wave 288

      Magic Angle Artifact 290

      13 Gradients 295

      Physical Gradients 296

      Logical Gradients 302

      14 MRI Math 313

      The Larmor Equation: W0 = γB0 314

      Acquisitions or Nex or NSA 314

      Scan Time Equations 315

      Pixel Size and Voxel Volume 317

      How to Convert Hz per Pixel to MHz 318

      In and Out of Phase TEs 319

      Dixon Method or Technique 320

      SNR and the 3D Sequence 321

      15 Parallel Imaging 325

      Parallel Imaging: What Is It? 325

      When and Where to Use the Speed 326

      Parallel Imaging: How Does It Work? 327

      Parallel Imaging: Pros and Cons 330

      16 IV Gadolinium 335

      Why We Use Gad 336

      How Does Gad Shorten the T1 of Tissues? 337

      The Blood–Brain Barrier 341

      Post Contrast T2 FLAIR Imaging 342

      Imaging Gadolinium 345

      Eovist® 347

      Glossary 351

      Suggested Reading 388

      Index 389

      Recently viewed products

      © 2026 Book Curl

        • American Express
        • Apple Pay
        • Diners Club
        • Discover
        • Google Pay
        • Maestro
        • Mastercard
        • PayPal
        • Shop Pay
        • Union Pay
        • Visa

        Login

        Forgot your password?

        Don't have an account yet?
        Create account