Description

Book Synopsis
The recently published book by the author, "Engineering Heat Transfer", already dealt with exact computation of heat exchangers and tube banks. In design c- putationthisisaccomplishedviacorrectivefactors;thelattermakesitpossibleto compute the actual mean temperature difference by starting from the logarithmic onerelativeto?uidsinparallel?oworcounter?ow. As far as veri?cation computation is concerned, corrective factors were int- ducedtocomputeacertaincharacteristicfactorcorrectly,asisfundamentalforthis typeofcomputation. Basedontheabove,theauthordecidedtoinvestigatefurther,re?ne,andwiden thistopic:theoutcomeofthisworkhasresultedinthishandbook. Newtypesofexchangerswereexamined;thecalculationwasre?nedtoproduce practicallyexactvaluesforthefactors. Thescopeoftheinvestigationwasincreased by widening the range of the starting factors. Furthermore, a greater number of valuestobeincludedinthetableswasconsidered. Finally,afewcharacteristicsof certainvaluesofthecorrectivefactorswerehighlighted. The?rstsectionisanintroduction;itsummarizesthefundamentalcriteriaofheat transferandproceedstoillustratethebehaviorof?uidsinbothparallelandcounter ?ow. Italsoshowshowtocomputethemeanisobaricspeci?cheatforsome? uids; itillustratesthesigni?canceofdesigncomputationandveri?cationcomputation. In addition,itillustrateshowtoproceedwithheatexchangersandtubebankstocarry outbothdesignandveri?cationcomputationcorrectly. AppendixAthenincludes36tablesasareferencefordesigncomputation,The tablescontainthecorrectivefactorsrequiredtoobtaintheactualmeantemperature differencebystartingfromthemeanlogarithmictemperaturedifferencerelativeto ?uidsinparallel?oworcounter?ow. Finally, Appendix B includes 35 tables for veri?cation computation. As far as heatexchangers areconcerned, itshowsthevaluesoffactor ? whichisrequired forthistypeofcomputation. Thevaluesofthecorrectivefactorsforcoilsandtube banksarealsopresented. Milano,Italy DonatelloAnnaratone v Notation c=speci?cheat(J/kgK) d=diameter(m) E=ef?ciencyfactor h=enthalpy(kJ/kg) k=thermalconductivity(W/mK) M=mass?owrate(kg/s) m=massmoisturepercentage(%) q=heatpertimeunit(W) 2 S=surface(m ) ? t=temperature( C) 2 U=overallheattransfercoef?cient(W/m K) x=thickness(m) 2 ? =heattransfercoef?cient(W/m K) ? =characteristicfactor ? =characteristicfactor ? =ef?ciency ? =correctivefactor ? =correctivefactor ? =characteristicfactor ? ?t =temperaturedifference( C) vii viii Notation Superscripts =heating?uid =heated?uid Subscripts c=counter?ow e=exchanger i=inside l=logarithmic m=mean o=outside p=constantpressure(isobaric),parallel?ow w=wall 1=inlet(forheatingorheated?uid) 2=outlet(forheatingorheated?uid) Contents 1 Introduction to Computation ...1 1. 1 GeneralConsiderations ...1 1. 2 MeanIsobaricSpeci?cHeat ...3 1. 2. 1 WaterandSuperheatedSteam ...4 1. 2. 2 AirandOtherGases...4 2 Design Computation...7 2. 1 Introduction ...7 2. 2 FluidsinParallelFloworinCounterFlow ...8 2. 3 TheMeanDifferenceinTemperatureinReality ...12 2. 3. 1 FluidsinCrossFlow...14 2. 3. 2 HeatExchangers...15 2. 3. 3 Coils...19 2. 3. 4 TubeBankswithVariousPassagesoftheExternalFluid . 21 3 Veri?cation Computation ...25 3. 1 Introduction ...25 3. 2 FluidsinParallelFloworinCounterFlow ...25 3. 3 Factor?inRealCases...33 3. 3. 1 FluidswithCrossFlow ...

Table of Contents
to Computation.- Design Computation.- Verification Computation.

Handbook for Heat Exchangers and Tube Banks design

Product form

£113.99

Includes FREE delivery

RRP £119.99 – you save £6.00 (5%)

Order before 4pm today for delivery by Thu 18 Dec 2025.

A Hardback by Donatello Annaratone

15 in stock


    View other formats and editions of Handbook for Heat Exchangers and Tube Banks design by Donatello Annaratone

    Publisher: Springer-Verlag Berlin and Heidelberg GmbH & Co. KG
    Publication Date: 31/07/2010
    ISBN13: 9783642133084, 978-3642133084
    ISBN10: 3642133088

    Description

    Book Synopsis
    The recently published book by the author, "Engineering Heat Transfer", already dealt with exact computation of heat exchangers and tube banks. In design c- putationthisisaccomplishedviacorrectivefactors;thelattermakesitpossibleto compute the actual mean temperature difference by starting from the logarithmic onerelativeto?uidsinparallel?oworcounter?ow. As far as veri?cation computation is concerned, corrective factors were int- ducedtocomputeacertaincharacteristicfactorcorrectly,asisfundamentalforthis typeofcomputation. Basedontheabove,theauthordecidedtoinvestigatefurther,re?ne,andwiden thistopic:theoutcomeofthisworkhasresultedinthishandbook. Newtypesofexchangerswereexamined;thecalculationwasre?nedtoproduce practicallyexactvaluesforthefactors. Thescopeoftheinvestigationwasincreased by widening the range of the starting factors. Furthermore, a greater number of valuestobeincludedinthetableswasconsidered. Finally,afewcharacteristicsof certainvaluesofthecorrectivefactorswerehighlighted. The?rstsectionisanintroduction;itsummarizesthefundamentalcriteriaofheat transferandproceedstoillustratethebehaviorof?uidsinbothparallelandcounter ?ow. Italsoshowshowtocomputethemeanisobaricspeci?cheatforsome? uids; itillustratesthesigni?canceofdesigncomputationandveri?cationcomputation. In addition,itillustrateshowtoproceedwithheatexchangersandtubebankstocarry outbothdesignandveri?cationcomputationcorrectly. AppendixAthenincludes36tablesasareferencefordesigncomputation,The tablescontainthecorrectivefactorsrequiredtoobtaintheactualmeantemperature differencebystartingfromthemeanlogarithmictemperaturedifferencerelativeto ?uidsinparallel?oworcounter?ow. Finally, Appendix B includes 35 tables for veri?cation computation. As far as heatexchangers areconcerned, itshowsthevaluesoffactor ? whichisrequired forthistypeofcomputation. Thevaluesofthecorrectivefactorsforcoilsandtube banksarealsopresented. Milano,Italy DonatelloAnnaratone v Notation c=speci?cheat(J/kgK) d=diameter(m) E=ef?ciencyfactor h=enthalpy(kJ/kg) k=thermalconductivity(W/mK) M=mass?owrate(kg/s) m=massmoisturepercentage(%) q=heatpertimeunit(W) 2 S=surface(m ) ? t=temperature( C) 2 U=overallheattransfercoef?cient(W/m K) x=thickness(m) 2 ? =heattransfercoef?cient(W/m K) ? =characteristicfactor ? =characteristicfactor ? =ef?ciency ? =correctivefactor ? =correctivefactor ? =characteristicfactor ? ?t =temperaturedifference( C) vii viii Notation Superscripts =heating?uid =heated?uid Subscripts c=counter?ow e=exchanger i=inside l=logarithmic m=mean o=outside p=constantpressure(isobaric),parallel?ow w=wall 1=inlet(forheatingorheated?uid) 2=outlet(forheatingorheated?uid) Contents 1 Introduction to Computation ...1 1. 1 GeneralConsiderations ...1 1. 2 MeanIsobaricSpeci?cHeat ...3 1. 2. 1 WaterandSuperheatedSteam ...4 1. 2. 2 AirandOtherGases...4 2 Design Computation...7 2. 1 Introduction ...7 2. 2 FluidsinParallelFloworinCounterFlow ...8 2. 3 TheMeanDifferenceinTemperatureinReality ...12 2. 3. 1 FluidsinCrossFlow...14 2. 3. 2 HeatExchangers...15 2. 3. 3 Coils...19 2. 3. 4 TubeBankswithVariousPassagesoftheExternalFluid . 21 3 Veri?cation Computation ...25 3. 1 Introduction ...25 3. 2 FluidsinParallelFloworinCounterFlow ...25 3. 3 Factor?inRealCases...33 3. 3. 1 FluidswithCrossFlow ...

    Table of Contents
    to Computation.- Design Computation.- Verification Computation.

    Recently viewed products

    © 2025 Book Curl

      • American Express
      • Apple Pay
      • Diners Club
      • Discover
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account