Description

Book Synopsis

Today, hundreds of millions of people drink contaminated water without knowing it. Yet water treatment technologies can effectively eliminate contamination and can supply urban and rural populations with safe drinking water in a secure way.

For almost two centuries, the huge number of treatments available to guarantee water quality has grown alongside technological progress, the strengthening of industry norms and the reinforcement of consumer expectations. New treatment methods have been developed according to the advancement of knowledge and new sanitary regulations.

This five-volume book sets out to clearly present the variety of treatments available along with their performance, limitations and conditions of use as well as ways to combine them to produce safe drinking water, which is a basic need essential to everyday life.

The author shares his expertise acquired at Veolia, a company that is a world leader in water services and sanitation, desalination of sea water and the recycling of wastewater. Founded in France in 1853 to bring safe water to populations and to protect them from waterborne epidemics which ravaged cities, its history is intertwined with that of water treatment.



Table of Contents

Chapter 17 Microfiltration and Ultrafiltration 1

17.1 UF and MF: cut-off 2

17.2 UF and MF: materials 6

17.2.1 Cellulose acetate 6

17.2.2 Polypropylene 7

17.2.3 Polyacrylonitrile 7

17.2.4 Polyether sulfone/polysulfone 7

17.2.5 Polyvinylidene fluoride 8

17.3 UF and MF: membrane types 8

17.4 UF and MF: implementation of membranes under pressure 11

17.4.1 Horizontal-vertical configuration 13

17.4.2 Submerged membranes 17

17.5 Filtration modes: frontal or tangential 19

17.5.1 Batch operation: filtration-backwash 21

17.5.2 Filtration direction 21

17.6 Sizing parameters: membrane selection 22

17.7 Sizing parameters: horizontal or vertical configuration 25

17.8 Sizing parameters: flow 25

17.8.1 Instantaneous flow and net flow 26

17.8.2 Transmembrane pressure 31

17.8.3 Resistance 33

17.8.4 Permeability 33

17.8.5 Principle of the calculation of the membrane surface and water losses 35

17.8.6 Pre-filters 37

17.9 Operating parameters 37

17.9.1 Evolution of the permeability 37

17.9.2 Clogging 38

17.9.3 Frequency and conditions of hydraulic and chemical backwashing 46

17.9.4 Frequency and conditions of CIP 53

17.9.5 Membrane integrity 56

17.10 MF and UF’s place in a treatment process 62

17.10.1 Turbidity and SS 63

17.10.2 TOC (and UV254) 63

17.10.3 Algae 63

17.10.4 Iron and manganese 63

17.11 Combination of coagulation and UF membranes 71

17.12 Combination of PAC and UF 75

17.13 Performance and guarantees 76

17.13.1 Turbidity 76

17.13.2 Supplier warranty on the life of the membranes 86

17.14 Advantages of MF and UF 87

17.15 Veolia’s experience 87

17.16 Appendix: sheets 92

17.17 References 107

Chapter 18 Nanofiltration and Reverse Osmosis 111

18.1 Membranes 112

18.1.1 Materials 112

18.1.2 Membrane element configurations 115

18.2 Principles of operation and separation 119

18.2.1 Conceptual principle 119

18.2.2 Molecular weight cut-off 124

18.3 Treatment process including high-pressure membranes and parameters to be considered 127

18.3.1 Particulates and SS 127

18.3.2 Particle count 128

18.3.3 Conductivity 128

18.3.4 The SDI or MFI: clogging indices 128

18.3.5 The SDI 128

18.3.6 The MFI 130

18.3.7 Salts and metals 131

18.3.8 Biological clogging 132

18.3.9 Undesirable substances 133

18.3.10 Limit values of compounds at the inlet of high-pressure membranes 133

18.4 Sizing parameters 134

18.4.1 Temperature 134

18.4.2 Implementation configuration 134

18.4.3 Calculation of the osmotic pressure 138

18.4.4 Mass flow diagram 139

18.4.5 Salt passage 140

18.4.6 Concentration factor 140

18.4.7 Hydraulic pressure loss 140

18.4.8 Pressure tubes and number of modules per tube 141

18.5 Chemical conditioning of pre-treated water 143

18.5.1 Calculation of saturation indices and antiscalant dosage 143

18.5.2 Choice and implementation of the antiscalant 146

18.5.3 pH adjustment at the membrane inlet 147

18.5.4 Choice and application of the acid 148

18.5.5 Influence of sulfates 148

18.6 Design and implementation 148

18.6.1 Pre-treatment 148

18.6.2 Treatment processes 149

18.6.3 Membrane station 152

18.6.4 Post-treatment 158

18.6.5 Cleaning units in place 159

18.7 Functional and operating parameters 162

18.7.1 Basic principles 162

18.7.2 Permeability (Lp) 166

18.7.3 Longitudinal pressure drop (ΔPfc) 166

18.7.4 Hydraulic resistance 167

18.7.5 Energy 167

18.7.6 Sdi 168

18.7.7 Chemical cleaning 168

18.7.8 The fate of concentrates and used washing solutions 168

18.7.9 Methods for assessing the impact of concentrate discharges in the natural environment 171

18.8 High-pressure membrane performance 174

18.8.1 Organic matter 175

18.8.2 Pesticides, drug residues, endocrine disruptors and industrial residues 176

18.8.3 Various toxic and undesirable substances 177

18.8.4 Salts 177

18.8.5 Micro-organisms 178

18.8.6 Overall performance 179

18.9 Lifetime warranties 179

18.10 Parameters affecting the performance of NF membranes 180

18.10.1 Taking clogging into account 181

18.11 Monitoring and control parameters: standardization of raw data 182

18.12 Veolia’s experience: examples of treatment processes 184

18.12.1 Surface water No 1 184

18.12.2 Surface water No 2 188

18.12.3 Groundwater No 1 193

18.12.4 Groundwater No 2 195

18.13 References 200

Chapter 19 Desalination by Reverse Osmosis 205

19.1 Characterization of the water to be treated 205

19.1.1 Physical characteristics 207

19.1.2 Chemical composition: ionic content 214

19.1.3 Chemical composition: organic substances 224

19.2 Fields of application 234

19.3 Operating principle of RO 234

19.4 The membranes used in desalination 237

19.5 Sizing parameters 238

19.5.1 Flow 239

19.5.2 Concentration polarization 240

19.5.3 Conversion rate 240

19.5.4 Passage rate and rejection rate in salts 241

19.5.5 Influence of the temperature 242

19.5.6 Determining the number of modules and pressure tubes 243

19.6 Implementation 244

19.6.1 Membranes 244

19.6.2 Pressure tube 245

19.6.3 Pass 246

19.7 Pre-treatment 246

19.7.1 Pre-treatment selection 246

19.7.2 Pre-treatment systems 250

19.8 Pre-chlorination 254

19.8.1 Pre-chlorination and development of micro- and macro-organisms 254

19.8.2 Implementation of chlorination 257

19.8.3 pH adjustment 263

19.8.4 Direct filtration 263

19.8.5 Chemical conditions of implementation 273

19.8.6 Flotation 276

19.8.7 Settling 281

19.8.8 Membranes (UF and MF) 282

19.8.9 Conclusions on pre-treatment with UF membranes 291

19.9 Energy consumption 292

19.9.1 Energy consumption without recovery 292

19.9.2 Energy consumption with recovery 293

19.9.3 Hydraulic exchanger systems 293

19.10 Operating parameters 305

19.10.1 Relationship between conductivity and salt concentration 305

19.10.2 Controlling RO membrane clogging 306

19.11 Performance of RO membranes used in desalination 307

19.11.1 Boron removal 307

19.12 Post-treatment 315

19.12.1 Indicators characterizing the aggressiveness or corrosiveness of the water 317

19.12.2 Application to desalinated water 320

19.12.3 Treatments 322

19.13 Monitoring and control parameters 336

19.13.1 Standardization of raw data 336

19.13.2 Bromates 338

19.14 Veolia’s new processes applied to seawater desalination 339

19.14.1 Flotation with the Spidflow® process 339

19.14.2 Spidflow® filter process applied to seawater desalination 344

19.14.3 BiopROtector 349

19.14.4 Barrel (SIDEM Veolia) 353

19.14.5 Hiprode 355

19.15 Packaged solutions in desalination 358

19.16 Veolia’s experience (HP membranes) 360

19.17 References 374

Index 385

Summaries of other volumes 387

Drinking Water Treatment, Membranes Applied to

    Product form

    £118.80

    Includes FREE delivery

    RRP £132.00 – you save £13.20 (10%)

    Order before 4pm tomorrow for delivery by Mon 10 Aug 2026.

    A Hardback by Kader Gaid

      Trusted by thousands of customers. See 2,385+ Customer Reviews

      View other formats and editions of Drinking Water Treatment, Membranes Applied to by Kader Gaid

      Publisher: ISTE Ltd and John Wiley & Sons Inc
      Publication Date: Publication Date: 31/07/2023
      ISBN13: 9781786307866, 978-1786307866
      ISBN10: 1786307863

      Description

      Book Synopsis

      Today, hundreds of millions of people drink contaminated water without knowing it. Yet water treatment technologies can effectively eliminate contamination and can supply urban and rural populations with safe drinking water in a secure way.

      For almost two centuries, the huge number of treatments available to guarantee water quality has grown alongside technological progress, the strengthening of industry norms and the reinforcement of consumer expectations. New treatment methods have been developed according to the advancement of knowledge and new sanitary regulations.

      This five-volume book sets out to clearly present the variety of treatments available along with their performance, limitations and conditions of use as well as ways to combine them to produce safe drinking water, which is a basic need essential to everyday life.

      The author shares his expertise acquired at Veolia, a company that is a world leader in water services and sanitation, desalination of sea water and the recycling of wastewater. Founded in France in 1853 to bring safe water to populations and to protect them from waterborne epidemics which ravaged cities, its history is intertwined with that of water treatment.



      Table of Contents

      Chapter 17 Microfiltration and Ultrafiltration 1

      17.1 UF and MF: cut-off 2

      17.2 UF and MF: materials 6

      17.2.1 Cellulose acetate 6

      17.2.2 Polypropylene 7

      17.2.3 Polyacrylonitrile 7

      17.2.4 Polyether sulfone/polysulfone 7

      17.2.5 Polyvinylidene fluoride 8

      17.3 UF and MF: membrane types 8

      17.4 UF and MF: implementation of membranes under pressure 11

      17.4.1 Horizontal-vertical configuration 13

      17.4.2 Submerged membranes 17

      17.5 Filtration modes: frontal or tangential 19

      17.5.1 Batch operation: filtration-backwash 21

      17.5.2 Filtration direction 21

      17.6 Sizing parameters: membrane selection 22

      17.7 Sizing parameters: horizontal or vertical configuration 25

      17.8 Sizing parameters: flow 25

      17.8.1 Instantaneous flow and net flow 26

      17.8.2 Transmembrane pressure 31

      17.8.3 Resistance 33

      17.8.4 Permeability 33

      17.8.5 Principle of the calculation of the membrane surface and water losses 35

      17.8.6 Pre-filters 37

      17.9 Operating parameters 37

      17.9.1 Evolution of the permeability 37

      17.9.2 Clogging 38

      17.9.3 Frequency and conditions of hydraulic and chemical backwashing 46

      17.9.4 Frequency and conditions of CIP 53

      17.9.5 Membrane integrity 56

      17.10 MF and UF’s place in a treatment process 62

      17.10.1 Turbidity and SS 63

      17.10.2 TOC (and UV254) 63

      17.10.3 Algae 63

      17.10.4 Iron and manganese 63

      17.11 Combination of coagulation and UF membranes 71

      17.12 Combination of PAC and UF 75

      17.13 Performance and guarantees 76

      17.13.1 Turbidity 76

      17.13.2 Supplier warranty on the life of the membranes 86

      17.14 Advantages of MF and UF 87

      17.15 Veolia’s experience 87

      17.16 Appendix: sheets 92

      17.17 References 107

      Chapter 18 Nanofiltration and Reverse Osmosis 111

      18.1 Membranes 112

      18.1.1 Materials 112

      18.1.2 Membrane element configurations 115

      18.2 Principles of operation and separation 119

      18.2.1 Conceptual principle 119

      18.2.2 Molecular weight cut-off 124

      18.3 Treatment process including high-pressure membranes and parameters to be considered 127

      18.3.1 Particulates and SS 127

      18.3.2 Particle count 128

      18.3.3 Conductivity 128

      18.3.4 The SDI or MFI: clogging indices 128

      18.3.5 The SDI 128

      18.3.6 The MFI 130

      18.3.7 Salts and metals 131

      18.3.8 Biological clogging 132

      18.3.9 Undesirable substances 133

      18.3.10 Limit values of compounds at the inlet of high-pressure membranes 133

      18.4 Sizing parameters 134

      18.4.1 Temperature 134

      18.4.2 Implementation configuration 134

      18.4.3 Calculation of the osmotic pressure 138

      18.4.4 Mass flow diagram 139

      18.4.5 Salt passage 140

      18.4.6 Concentration factor 140

      18.4.7 Hydraulic pressure loss 140

      18.4.8 Pressure tubes and number of modules per tube 141

      18.5 Chemical conditioning of pre-treated water 143

      18.5.1 Calculation of saturation indices and antiscalant dosage 143

      18.5.2 Choice and implementation of the antiscalant 146

      18.5.3 pH adjustment at the membrane inlet 147

      18.5.4 Choice and application of the acid 148

      18.5.5 Influence of sulfates 148

      18.6 Design and implementation 148

      18.6.1 Pre-treatment 148

      18.6.2 Treatment processes 149

      18.6.3 Membrane station 152

      18.6.4 Post-treatment 158

      18.6.5 Cleaning units in place 159

      18.7 Functional and operating parameters 162

      18.7.1 Basic principles 162

      18.7.2 Permeability (Lp) 166

      18.7.3 Longitudinal pressure drop (ΔPfc) 166

      18.7.4 Hydraulic resistance 167

      18.7.5 Energy 167

      18.7.6 Sdi 168

      18.7.7 Chemical cleaning 168

      18.7.8 The fate of concentrates and used washing solutions 168

      18.7.9 Methods for assessing the impact of concentrate discharges in the natural environment 171

      18.8 High-pressure membrane performance 174

      18.8.1 Organic matter 175

      18.8.2 Pesticides, drug residues, endocrine disruptors and industrial residues 176

      18.8.3 Various toxic and undesirable substances 177

      18.8.4 Salts 177

      18.8.5 Micro-organisms 178

      18.8.6 Overall performance 179

      18.9 Lifetime warranties 179

      18.10 Parameters affecting the performance of NF membranes 180

      18.10.1 Taking clogging into account 181

      18.11 Monitoring and control parameters: standardization of raw data 182

      18.12 Veolia’s experience: examples of treatment processes 184

      18.12.1 Surface water No 1 184

      18.12.2 Surface water No 2 188

      18.12.3 Groundwater No 1 193

      18.12.4 Groundwater No 2 195

      18.13 References 200

      Chapter 19 Desalination by Reverse Osmosis 205

      19.1 Characterization of the water to be treated 205

      19.1.1 Physical characteristics 207

      19.1.2 Chemical composition: ionic content 214

      19.1.3 Chemical composition: organic substances 224

      19.2 Fields of application 234

      19.3 Operating principle of RO 234

      19.4 The membranes used in desalination 237

      19.5 Sizing parameters 238

      19.5.1 Flow 239

      19.5.2 Concentration polarization 240

      19.5.3 Conversion rate 240

      19.5.4 Passage rate and rejection rate in salts 241

      19.5.5 Influence of the temperature 242

      19.5.6 Determining the number of modules and pressure tubes 243

      19.6 Implementation 244

      19.6.1 Membranes 244

      19.6.2 Pressure tube 245

      19.6.3 Pass 246

      19.7 Pre-treatment 246

      19.7.1 Pre-treatment selection 246

      19.7.2 Pre-treatment systems 250

      19.8 Pre-chlorination 254

      19.8.1 Pre-chlorination and development of micro- and macro-organisms 254

      19.8.2 Implementation of chlorination 257

      19.8.3 pH adjustment 263

      19.8.4 Direct filtration 263

      19.8.5 Chemical conditions of implementation 273

      19.8.6 Flotation 276

      19.8.7 Settling 281

      19.8.8 Membranes (UF and MF) 282

      19.8.9 Conclusions on pre-treatment with UF membranes 291

      19.9 Energy consumption 292

      19.9.1 Energy consumption without recovery 292

      19.9.2 Energy consumption with recovery 293

      19.9.3 Hydraulic exchanger systems 293

      19.10 Operating parameters 305

      19.10.1 Relationship between conductivity and salt concentration 305

      19.10.2 Controlling RO membrane clogging 306

      19.11 Performance of RO membranes used in desalination 307

      19.11.1 Boron removal 307

      19.12 Post-treatment 315

      19.12.1 Indicators characterizing the aggressiveness or corrosiveness of the water 317

      19.12.2 Application to desalinated water 320

      19.12.3 Treatments 322

      19.13 Monitoring and control parameters 336

      19.13.1 Standardization of raw data 336

      19.13.2 Bromates 338

      19.14 Veolia’s new processes applied to seawater desalination 339

      19.14.1 Flotation with the Spidflow® process 339

      19.14.2 Spidflow® filter process applied to seawater desalination 344

      19.14.3 BiopROtector 349

      19.14.4 Barrel (SIDEM Veolia) 353

      19.14.5 Hiprode 355

      19.15 Packaged solutions in desalination 358

      19.16 Veolia’s experience (HP membranes) 360

      19.17 References 374

      Index 385

      Summaries of other volumes 387

      Recently viewed products

      © 2026 Book Curl

        • American Express
        • Apple Pay
        • Diners Club
        • Discover
        • Google Pay
        • Maestro
        • Mastercard
        • PayPal
        • Shop Pay
        • Union Pay
        • Visa

        Login

        Forgot your password?

        Don't have an account yet?
        Create account