Description

Book Synopsis
The hemodynamic effect of the atria on the net performance of the heart is called atrial contribution (AC). AC is either linked to ventricular filling or to the systolic function of the heart, i.e. to the systolic volume or cardiac output. Several noninvasive methods for the quantification of AC are described in literature but none of them are routinely used in cardiac pacing centres due to the time-consuming nature of the methods, the limited reproducibility of measured values and observer dependency. The aim of these studies was to develop a method for determining optimal AV delay in patients treated by dual chamber pacing using an index (ACSp) that quantifies atrial contribution to the systolic volume of the left ventricle. The new method is based on the quantitative analysis of a beat to beat decrease in the amplitude of the pulse oximetry signal (SpO2). The change in the amplitudes is induced by a sudden drop of the stimulus to the right atrium, while maintaining the rate of ventricular stimuli at a constant level. The obtained ACSp is given as a percentage of the pulse amplitude of SpO2. The method is independent of the observer, non-invasive and relatively fast. In a group of 47 patients, remarkable similarities between ACSp and another atrial contribution index estimated using the tracings of invasively registered aortal pressure were demonstrated. In all investigated AV intervals of 50 to 250 ms, significant inter-individual variability of ACSp was discovered. The poorest hemodynamic effect was seen at AV delay of 50 ms (median ACSp of 10.4 % from 97 subjects). In 150 subjects, the following values of ACSp were obtained at AV delay of 200 ms: median 30 %, minimum 3.6 % and maximum 80.4 %. An increase in ACSp follows reduction of preload induced by administration of furosemide. This suggests that when preload decreases cardiac output is preserved by an increase in AC enforced by sympathetic activation.

Optimization of Paced AV Delay Using Atrial

    Product form

    £38.24

    Includes FREE delivery

    RRP £50.99 – you save £12.75 (25%)

    Order before 4pm tomorrow for delivery by Fri 31 Jul 2026.

    A Paperback / softback by Miroslav Mestan, Jiri Kvasnicka

    Out of stock

      Trusted by thousands of customers. See 2,385+ Customer Reviews

      View other formats and editions of Optimization of Paced AV Delay Using Atrial by Miroslav Mestan

      Publisher: Nova Science Publishers Inc
      Publication Date: Publication Date: 01/10/2008
      ISBN13: 9781604566048, 978-1604566048
      ISBN10: 1604566043

      Description

      Book Synopsis
      The hemodynamic effect of the atria on the net performance of the heart is called atrial contribution (AC). AC is either linked to ventricular filling or to the systolic function of the heart, i.e. to the systolic volume or cardiac output. Several noninvasive methods for the quantification of AC are described in literature but none of them are routinely used in cardiac pacing centres due to the time-consuming nature of the methods, the limited reproducibility of measured values and observer dependency. The aim of these studies was to develop a method for determining optimal AV delay in patients treated by dual chamber pacing using an index (ACSp) that quantifies atrial contribution to the systolic volume of the left ventricle. The new method is based on the quantitative analysis of a beat to beat decrease in the amplitude of the pulse oximetry signal (SpO2). The change in the amplitudes is induced by a sudden drop of the stimulus to the right atrium, while maintaining the rate of ventricular stimuli at a constant level. The obtained ACSp is given as a percentage of the pulse amplitude of SpO2. The method is independent of the observer, non-invasive and relatively fast. In a group of 47 patients, remarkable similarities between ACSp and another atrial contribution index estimated using the tracings of invasively registered aortal pressure were demonstrated. In all investigated AV intervals of 50 to 250 ms, significant inter-individual variability of ACSp was discovered. The poorest hemodynamic effect was seen at AV delay of 50 ms (median ACSp of 10.4 % from 97 subjects). In 150 subjects, the following values of ACSp were obtained at AV delay of 200 ms: median 30 %, minimum 3.6 % and maximum 80.4 %. An increase in ACSp follows reduction of preload induced by administration of furosemide. This suggests that when preload decreases cardiac output is preserved by an increase in AC enforced by sympathetic activation.

      Recently viewed products

      © 2026 Book Curl

        • American Express
        • Apple Pay
        • Diners Club
        • Discover
        • Google Pay
        • Maestro
        • Mastercard
        • PayPal
        • Shop Pay
        • Union Pay
        • Visa

        Login

        Forgot your password?

        Don't have an account yet?
        Create account