Description

Book Synopsis
Clear, comprehensive, and state of the art, the groundbreaking book on the emerging technology of direct analysis in real time mass spectrometry

Written by a noted expert in the field, Direct Analysis in Real Time Mass Spectrometry offers a review of the background and the most recent developments in DART-MS. Invented in 2005, DART-MS offers a wide range of applications for solving numerous analytical problems in various environments, including food science, forensics, and clinical analysis. The text presents an introduction to the history of the technology and includes information on the theoretical background, for exampleon the ionization mechanism. Chapters on sampling and coupling to different types of mass spectrometers are followed by a comprehensive discussion of a broad range of applications.

Unlike most other ionization methods, DART does not require laborious sample preparation, as ionization takes place directly on the sample surface. This makes the technique especially attractive for applications in forensics and food science. Comprehensive in scope, this vital text:

-Sets the standard on an important and emerging ionization technique
-Thoroughly discusses all the relevant aspects from instrumentation to applications
-Helps in solving numerous analytical problems in various applications, for example food science, forensics, environmental and clinical analysis
-Covers mechanisms, coupling to mass spectrometers, and includes information on challenges and disadvantages of the technique

Academics, analytical chemists, pharmaceutical chemists, clinical chemists, forensic scientists, and others will find this illuminating text a must-have resource for understanding the most recent developments in the field.

Table of Contents

Preface xv

About the Editor xvii

1 Introduction of Mass Spectrometry and Ambient Ionization Techniques 1
Yiyang Dong, Jiahui Liu, and Tianyang Guo

1.1 Evolution of Analytical Chemistry and Its Challenges in the Twenty-First Century 1

1.2 Historical Overview of Mass Spectrometry and Its Role in Contemporary Analytical Chemistry 5

1.3 Desorption/Ionization in Mass Spectrometry 12

1.3.1 Electronic Ionization (EI) 13

1.3.2 Chemical Ionization (CI) 14

1.3.3 Fast Atom/Ion Bombardment Ionization (FAB) 15

1.3.4 Electrospray Ionization (ESI) 16

1.3.5 Matrix Assisted Laser Desorption/Ionization (MALDI) 18

1.3.6 Field Desorption (FD) or Field Ionization (FI) 19

1.3.7 Plasma Desorption (PD) (ICP, LTP, DART) 19

1.4 Ambient Ionization and Direct Analysis in Real Time 21

1.4.1 Ambient Ionization 21

1.4.2 Direct Analysis in Real Time 24

1.4.2.1 Mechanisms 24

1.4.2.2 Parameters 27

1.4.2.3 Devices 29

References 30

2 DART Mass Spectrometry: Principle and Ionization Facilities 43
David Rondeau

2.1 Introduction 43

2.2 Metastable Gas Stream Formation 43

2.3 Ionization Mechanisms in Positive DART 45

2.3.1 Generation of Primary Ions by Ambient Air Ionization 46

2.3.2 Formation of the Protonated Molecules 50

2.3.3 Formation of the Ammonium Adducts 54

2.3.4 Formation of the Radical Cations and Their Fragments 55

2.3.5 Matrix Effects in DART Due to Sample Solvents 59

2.4 Ionization Mechanisms in Negative DART 65

2.4.1 Generation of Primary Ions by Ambient Air Ionization 65

2.4.2 Formation of Deprotonated Molecules 68

2.4.3 Formation of Radical Anions 69

2.4.4 Formation of Anionic Adducts 70

2.5 Some Parameters Affecting the DART Mass Spectra 71

2.5.1 Substitution of Helium by Nitrogen or Argon 71

2.5.2 The Temperature of the Gas Stream 75

2.5.3 The Internal Energy of Ions in DART-MS 76

2.6 Conclusion 78

References 78

3 Sampling and Analyte Enrichment Strategies for DART-MS 81
WenMa, Xianjiang Li, and Huwei Liu

3.1 Dilution Strategy for Sticky Sample Analysis 81

3.2 Purification Strategy for Eliminating the Matrix Interference 82

3.2.1 Liquid Phase Extraction 82

3.2.2 Solid Phase Extraction (SPE) 86

3.2.3 Solid Phase Microextraction (SPME) 87

3.3 Derivatization Strategy to Decrease Polarity and Enhance Volatility 89

3.4 Conclusions 91

References 91

4 Optimization of DART andMass Spectrometric Parameters 97
GuohuaWu andWushuang Li

4.1 Introduction 97

4.2 Effect ofWorking Gas Type, Gas Flow Rate, and Its Temperature 98

4.2.1 Gas Type 98

4.2.2 Gas Flow Rate 99

4.2.3 TheWorking Gas Temperature of DART Ionization Source 100

4.3 Effects of Grid Electrode Voltage and Sampling Speed 102

4.3.1 Effect of Grid Electrode Voltage 102

4.3.2 Effect of Sampling Speed 103

4.4 Effect of the SamplingMode 104

4.4.1 SamplingMethods 104

4.4.2 Position and Angle of the DART Ion Source 105

4.5 Effect of Ion Mode 106

4.6 Effect of Solvent Type and Reagents 108

4.7 Summary 109

References 109

5 Interfacing DART to Extend Analytical Capabilities 115
Yiding Zhang, Shuting Xu, and Yu Bai

5.1 Introduction 115

5.2 Interfacing DART with Different Separation Techniques 116

5.2.1 Solid Samples 116

5.2.2 Gaseous Samples 118

5.2.3 Liquid Samples 119

5.2.3.1 Liquid Chromatography 119

5.2.3.2 Capillary Electrophoresis 123

5.3 Techniques of Interfacing DART with Other Analytical Techniques 125

5.3.1 Surface Plasmon Resonance 125

5.3.2 Ion Mobility Spectrometry 126

5.4 Conclusion and Perspectives 129

References 129

6 Application of DART-MS in Foods and Agro-Products Analysis 133
Canping Pan and Lei Wang

6.1 Introduction 133

6.2 Applications of DART-MS in Agriculture and Food Science 134

6.2.1 DART-MS in Pesticide Residue Analysis 134

6.2.1.1 Fast Screening Purposes 134

6.2.1.2 Screening Highly Hazardous Pesticides in Agrochemical Formulations 140

6.2.1.3 QuantitativeMRM Residue Method 147

6.2.2 Veterinary Drug Residue Detection 148

6.2.3 Fast Detection of Melamine in Milk 149

6.2.4 Detection of Mycotoxins in Cereals 150

6.2.5 Food Component Rapid Analysis 151

6.2.6 Contaminations in Food Contact Materials (FCMs) 156

6.3 Conclusion 156

References 157

7 Application of DART-MS for Industrial Chemical Analysis 163
Qiang Ma

7.1 Application on Household Items 163

7.1.1 Polydimethylsiloxane (PDMS) Analysis in Articles for Daily Use 163

7.1.2 Identification of Sulfides in Drywall 165

7.1.3 Phosphoric Acid Esters Screening in Aqueous Samples 168

7.2 Application on Food Packaging Safety and Quality Control 172

7.2.1 Identification of PDMS in Food Packaging Materials 172

7.2.2 Identification of Polymer Additives in Food and Food Packaging 175

7.2.3 Identification of Residue Primary Aromatic Amines (PAAs) in Food Packaging Materials 176

7.3 Application on Pharmaceutical Products 177

7.3.1 Toxic Glycols Identification 177

7.3.2 Identification of Active Ingredients in Chinese Herbal Medicines 179

7.4 Application on Cosmetics Quality Control 182

7.4.1 Screening of Glucocorticoids Illegal Addition 182

7.5 Application on Other Industrial Chemical Fields 184

7.5.1 Ink Discrimination on Questioned Document 184

7.5.2 Ionic Liquids Identification 189

7.6 Conclusions 190

References 190

8 Application of Direct Analysis in Real Time Coupled toMass Spectrometry (DART-MS) for the Analysis of Environmental Contaminants 193
Maxime C. Bridoux and Sébastien Schramm

8.1 Introduction 193

8.2 Screening and Quantitative Analysis of Pesticides 194

8.3 Flame Retardants DART-MS Analysis 204

8.3.1 Organophosphorus Flame Retardants (OPFRs) 204

8.3.2 Brominated Flame Retardants (BFRs) 207

8.4 Use of DART-MS for the Analysis of Personal Care Products (PCPs) 210

8.4.1 Screening of Organic UV Filters inWater 210

8.4.2 Screening of Phthalic Acid Diesters 211

8.4.3 HPLC-DART-MS Analysis of Parabens 211

8.5 Use of DART-MS for the Analysis of Aerosols 212

8.5.1 Online DART for Aerosols Analysis 212

8.5.2 Offline DART Methods 213

8.5.3 Advantages and Limitations of DART-MS for Aerosols Characterization 213

8.6 Miscellaneous Environmental Application of DART-MS 214

8.7 Conclusions 215

References 216

9 Application of DART-MS in Clinical and Pharmacological Analysis 223
Yue Li

9.1 Introduction 223

9.2 Sample Preparation 224

9.3 Applications of DART-MS 225

9.3.1 Rapid Determination of Small Organic Compounds in Biological Samples 225

9.3.1.1 Analysis of a Bitter Herbal Medicine Gentiana scabra Root Extract 225

9.3.1.2 Simultaneous Determination of 3-Chlorotyrosine and 3-Nitrotyrosine in Human Plasma 226

9.3.1.3 Rapid Screening for Methamphetamine, 3,4-Methylene-dioxymethamphetamine, andTheir Metabolites in Urine 227

9.3.2 Newborn Screening for Phenylketonuria 227

9.3.3 DART-MS Analysis of Skin Metabolome Changes in Ultraviolet B-Induced Mice 228

9.3.4 Application in Detection of Breast Cancer 231

9.3.5 Transmission Mode DART-MS for Fast Untargeted Metabolic Fingerprinting 232

9.3.6 Applications of Confined DART Ion Source for Online In vivo Analysis of Human Breath 233

9.3.6.1 Real-Time Analysis of Exhaled Breath 234

9.3.6.2 Real-Time Monitoring of Oral Anesthetic Drug 235

9.4 Challenges and Limitations 236

9.5 Recent Advancements 237

References 238

10 DART-MS Applications in Pharmaceuticals 241
Karina G. Putri, Qianwen Wu, and Young P. Jang

10.1 Pharmaceutical Analysis 241

10.2 Quality Assurance 243

10.3 Illegal Active Pharmaceutical Ingredients and Counterfeit Drugs 244

10.4 Drug Development 247

References 251

11 Application of DART-MS in Natural Phytochemical Research 255
Vikas Bajpai, Awantika Singh, Brijesh Kumar, and Kunnath P. Madhusudanan

11.1 Introduction 255

11.2 Direct Analysis in Real Time (DART)Mass Spectrometry 256

11.3 DART-MS Parameter Optimization for Phytochemical Analysis 256

11.4 Applications of DART-MS in Phytochemical Research 257

11.4.1 Qualitative Phytochemical Analysis 257

11.4.2 Cell Culture Analysis 261

11.4.3 Analysis of Volatiles 261

11.4.4 Species Identification 262

11.4.5 Metabolic Profiling and Multivariate Analysis 263

11.4.6 Quantitative Analysis 274

11.5 Hyphenated DART-MS Techniques for Phytochemical Analysis 276

11.5.1 GC and HPLC-DART-MS 276

11.5.2 TLC/HPTLC-DART-MS 276

11.5.3 Capillary Electrophoresis-DART MS 277

11.5.4 DART-IMS-MS 277

11.5.5 Other Coupling Techniques 277

11.6 Improving Sensitivity of DART-MS for Phytochemical Analysis 278

11.6.1 Solvents and Gases 278

11.6.2 Matrix Suppression 279

11.7 DART -MS as Process Analytical Technology 279

11.8 Future Perspective 280

References 280

12 Miscellaneous Applications of DART-MS 291
Yoshihito Okada

12.1 Introduction 291

12.2 Usefulness of Negative-IonMode 292

12.3 Application to Archeology and Conservation 293

12.4 Application by Using TLC 293

12.5 Application to Low Volatility, ChemicalWarfare, and Homeland Security 294

12.6 Pheromone Profiles from Live Animals in Parallel with Behavior 295

12.7 Application to Distinction of Plants with Similarity 296

12.8 Application to Space 298

12.9 Application to Bituminous Coals 298

12.10 Application to Detection of Nicotine 298

12.11 Other Potential Applications of DART-MS 299

12.11.1 Instantaneous Screening for Counterfeit Drugs with No Sample Preparation [26-1] 299

12.11.2 Direct Analysis of Drugs in Pills and Capsules with No Sample Preparation [26-2] 300

12.11.3 Detection of Lycopene in Tomato Skin [26-3] 300

12.11.4 Distribution of Capsaicin in Chili Peppers [26-4] 302

12.11.5 Detection of Unstable Compound Released by Chopped Chives [26-5] 302

12.11.6 Rapid Detection of Fungicide in Orange Peel [26-6] 304

12.11.7 "Laundry Detective": Identification of a Stain [26-7] 304

12.11.8 Detection of the Peroxide Explosives TATP and HMTD [26-8] 306

12.11.9 Instantaneous Detection of Explosives on Clothing [26-9] 306

12.11.10 Rapid Detection and Exact Mass Measurements of Trace Components in a Herbicide [26-10] 308

12.11.11 Rapid Analysis of p-Phenylenediamine Antioxidants in Rubber [26-11] 308

Acknowledgment 309

References 309

13 Inherent Limitations and Prospects of DART-MS 313
Tim T. Häbe, Matthias Nitsch, and Gertrud E. Morlock

13.1 Aspects of Inherent Limitations of DART-MS 313

13.1.1 Gas Settings 314

13.1.1.1 Type of Gas 314

13.1.1.2 Gas Temperature 314

13.1.1.3 Gas Flow Rate 317

13.1.2 Voltage of Electrodes 317

13.1.3 Sample Introduction and Positioning 318

13.1.4 Detection System and Mass Range 318

13.1.5 Matrix Effects and the Need for Chromatography 319

13.1.6 Buffer and Salt Effects 321

13.1.7 Sample Carrier and Solvent 322

13.1.8 Humidity Effects 322

13.1.9 Use of Isotopically Labeled Standards 322

13.1.10 Dopant and Derivatization 323

13.2 DART versus Other Ambient Ion Sources 324

13.3 Prospects of DART-MS 326

13.3.1 Automation and Miniaturized DART-MS 326

13.3.2 Sample Preparation, Preconcentration, and Introduction 327

13.3.3 Ion Focusing and Flexible Ion Transportation 327

13.3.4 Quantitative Surface Scanning and Imaging by DART-MS 328

13.3.5 Hyphenation of Effect-Directed Analysis and DART-MS 331

13.3.6 Thermal Separations by Temperature Gradients 331

13.3.7 Aerosol, in situ and in stillo Chemical Reaction and Kinetic Monitoring 332

13.3.8 High Resolution and Data Analysis 332

13.4 Concluding Remarks 333

References 333

Index 345

Direct Analysis in Real Time Mass Spectrometry: Principles and Practices of DART-MS

    Product form

    £999.99

    Includes FREE delivery

    A Hardback by Yiyang Dong

    Out of stock

      Trusted by thousands of customers. See 2,385+ Customer Reviews

      View other formats and editions of Direct Analysis in Real Time Mass Spectrometry: Principles and Practices of DART-MS by Yiyang Dong

      Publisher: Wiley-VCH Verlag GmbH
      Publication Date: 07/02/2018
      ISBN13: 9783527341849, 978-3527341849
      ISBN10: 3527341846

      Description

      Book Synopsis
      Clear, comprehensive, and state of the art, the groundbreaking book on the emerging technology of direct analysis in real time mass spectrometry

      Written by a noted expert in the field, Direct Analysis in Real Time Mass Spectrometry offers a review of the background and the most recent developments in DART-MS. Invented in 2005, DART-MS offers a wide range of applications for solving numerous analytical problems in various environments, including food science, forensics, and clinical analysis. The text presents an introduction to the history of the technology and includes information on the theoretical background, for exampleon the ionization mechanism. Chapters on sampling and coupling to different types of mass spectrometers are followed by a comprehensive discussion of a broad range of applications.

      Unlike most other ionization methods, DART does not require laborious sample preparation, as ionization takes place directly on the sample surface. This makes the technique especially attractive for applications in forensics and food science. Comprehensive in scope, this vital text:

      -Sets the standard on an important and emerging ionization technique
      -Thoroughly discusses all the relevant aspects from instrumentation to applications
      -Helps in solving numerous analytical problems in various applications, for example food science, forensics, environmental and clinical analysis
      -Covers mechanisms, coupling to mass spectrometers, and includes information on challenges and disadvantages of the technique

      Academics, analytical chemists, pharmaceutical chemists, clinical chemists, forensic scientists, and others will find this illuminating text a must-have resource for understanding the most recent developments in the field.

      Table of Contents

      Preface xv

      About the Editor xvii

      1 Introduction of Mass Spectrometry and Ambient Ionization Techniques 1
      Yiyang Dong, Jiahui Liu, and Tianyang Guo

      1.1 Evolution of Analytical Chemistry and Its Challenges in the Twenty-First Century 1

      1.2 Historical Overview of Mass Spectrometry and Its Role in Contemporary Analytical Chemistry 5

      1.3 Desorption/Ionization in Mass Spectrometry 12

      1.3.1 Electronic Ionization (EI) 13

      1.3.2 Chemical Ionization (CI) 14

      1.3.3 Fast Atom/Ion Bombardment Ionization (FAB) 15

      1.3.4 Electrospray Ionization (ESI) 16

      1.3.5 Matrix Assisted Laser Desorption/Ionization (MALDI) 18

      1.3.6 Field Desorption (FD) or Field Ionization (FI) 19

      1.3.7 Plasma Desorption (PD) (ICP, LTP, DART) 19

      1.4 Ambient Ionization and Direct Analysis in Real Time 21

      1.4.1 Ambient Ionization 21

      1.4.2 Direct Analysis in Real Time 24

      1.4.2.1 Mechanisms 24

      1.4.2.2 Parameters 27

      1.4.2.3 Devices 29

      References 30

      2 DART Mass Spectrometry: Principle and Ionization Facilities 43
      David Rondeau

      2.1 Introduction 43

      2.2 Metastable Gas Stream Formation 43

      2.3 Ionization Mechanisms in Positive DART 45

      2.3.1 Generation of Primary Ions by Ambient Air Ionization 46

      2.3.2 Formation of the Protonated Molecules 50

      2.3.3 Formation of the Ammonium Adducts 54

      2.3.4 Formation of the Radical Cations and Their Fragments 55

      2.3.5 Matrix Effects in DART Due to Sample Solvents 59

      2.4 Ionization Mechanisms in Negative DART 65

      2.4.1 Generation of Primary Ions by Ambient Air Ionization 65

      2.4.2 Formation of Deprotonated Molecules 68

      2.4.3 Formation of Radical Anions 69

      2.4.4 Formation of Anionic Adducts 70

      2.5 Some Parameters Affecting the DART Mass Spectra 71

      2.5.1 Substitution of Helium by Nitrogen or Argon 71

      2.5.2 The Temperature of the Gas Stream 75

      2.5.3 The Internal Energy of Ions in DART-MS 76

      2.6 Conclusion 78

      References 78

      3 Sampling and Analyte Enrichment Strategies for DART-MS 81
      WenMa, Xianjiang Li, and Huwei Liu

      3.1 Dilution Strategy for Sticky Sample Analysis 81

      3.2 Purification Strategy for Eliminating the Matrix Interference 82

      3.2.1 Liquid Phase Extraction 82

      3.2.2 Solid Phase Extraction (SPE) 86

      3.2.3 Solid Phase Microextraction (SPME) 87

      3.3 Derivatization Strategy to Decrease Polarity and Enhance Volatility 89

      3.4 Conclusions 91

      References 91

      4 Optimization of DART andMass Spectrometric Parameters 97
      GuohuaWu andWushuang Li

      4.1 Introduction 97

      4.2 Effect ofWorking Gas Type, Gas Flow Rate, and Its Temperature 98

      4.2.1 Gas Type 98

      4.2.2 Gas Flow Rate 99

      4.2.3 TheWorking Gas Temperature of DART Ionization Source 100

      4.3 Effects of Grid Electrode Voltage and Sampling Speed 102

      4.3.1 Effect of Grid Electrode Voltage 102

      4.3.2 Effect of Sampling Speed 103

      4.4 Effect of the SamplingMode 104

      4.4.1 SamplingMethods 104

      4.4.2 Position and Angle of the DART Ion Source 105

      4.5 Effect of Ion Mode 106

      4.6 Effect of Solvent Type and Reagents 108

      4.7 Summary 109

      References 109

      5 Interfacing DART to Extend Analytical Capabilities 115
      Yiding Zhang, Shuting Xu, and Yu Bai

      5.1 Introduction 115

      5.2 Interfacing DART with Different Separation Techniques 116

      5.2.1 Solid Samples 116

      5.2.2 Gaseous Samples 118

      5.2.3 Liquid Samples 119

      5.2.3.1 Liquid Chromatography 119

      5.2.3.2 Capillary Electrophoresis 123

      5.3 Techniques of Interfacing DART with Other Analytical Techniques 125

      5.3.1 Surface Plasmon Resonance 125

      5.3.2 Ion Mobility Spectrometry 126

      5.4 Conclusion and Perspectives 129

      References 129

      6 Application of DART-MS in Foods and Agro-Products Analysis 133
      Canping Pan and Lei Wang

      6.1 Introduction 133

      6.2 Applications of DART-MS in Agriculture and Food Science 134

      6.2.1 DART-MS in Pesticide Residue Analysis 134

      6.2.1.1 Fast Screening Purposes 134

      6.2.1.2 Screening Highly Hazardous Pesticides in Agrochemical Formulations 140

      6.2.1.3 QuantitativeMRM Residue Method 147

      6.2.2 Veterinary Drug Residue Detection 148

      6.2.3 Fast Detection of Melamine in Milk 149

      6.2.4 Detection of Mycotoxins in Cereals 150

      6.2.5 Food Component Rapid Analysis 151

      6.2.6 Contaminations in Food Contact Materials (FCMs) 156

      6.3 Conclusion 156

      References 157

      7 Application of DART-MS for Industrial Chemical Analysis 163
      Qiang Ma

      7.1 Application on Household Items 163

      7.1.1 Polydimethylsiloxane (PDMS) Analysis in Articles for Daily Use 163

      7.1.2 Identification of Sulfides in Drywall 165

      7.1.3 Phosphoric Acid Esters Screening in Aqueous Samples 168

      7.2 Application on Food Packaging Safety and Quality Control 172

      7.2.1 Identification of PDMS in Food Packaging Materials 172

      7.2.2 Identification of Polymer Additives in Food and Food Packaging 175

      7.2.3 Identification of Residue Primary Aromatic Amines (PAAs) in Food Packaging Materials 176

      7.3 Application on Pharmaceutical Products 177

      7.3.1 Toxic Glycols Identification 177

      7.3.2 Identification of Active Ingredients in Chinese Herbal Medicines 179

      7.4 Application on Cosmetics Quality Control 182

      7.4.1 Screening of Glucocorticoids Illegal Addition 182

      7.5 Application on Other Industrial Chemical Fields 184

      7.5.1 Ink Discrimination on Questioned Document 184

      7.5.2 Ionic Liquids Identification 189

      7.6 Conclusions 190

      References 190

      8 Application of Direct Analysis in Real Time Coupled toMass Spectrometry (DART-MS) for the Analysis of Environmental Contaminants 193
      Maxime C. Bridoux and Sébastien Schramm

      8.1 Introduction 193

      8.2 Screening and Quantitative Analysis of Pesticides 194

      8.3 Flame Retardants DART-MS Analysis 204

      8.3.1 Organophosphorus Flame Retardants (OPFRs) 204

      8.3.2 Brominated Flame Retardants (BFRs) 207

      8.4 Use of DART-MS for the Analysis of Personal Care Products (PCPs) 210

      8.4.1 Screening of Organic UV Filters inWater 210

      8.4.2 Screening of Phthalic Acid Diesters 211

      8.4.3 HPLC-DART-MS Analysis of Parabens 211

      8.5 Use of DART-MS for the Analysis of Aerosols 212

      8.5.1 Online DART for Aerosols Analysis 212

      8.5.2 Offline DART Methods 213

      8.5.3 Advantages and Limitations of DART-MS for Aerosols Characterization 213

      8.6 Miscellaneous Environmental Application of DART-MS 214

      8.7 Conclusions 215

      References 216

      9 Application of DART-MS in Clinical and Pharmacological Analysis 223
      Yue Li

      9.1 Introduction 223

      9.2 Sample Preparation 224

      9.3 Applications of DART-MS 225

      9.3.1 Rapid Determination of Small Organic Compounds in Biological Samples 225

      9.3.1.1 Analysis of a Bitter Herbal Medicine Gentiana scabra Root Extract 225

      9.3.1.2 Simultaneous Determination of 3-Chlorotyrosine and 3-Nitrotyrosine in Human Plasma 226

      9.3.1.3 Rapid Screening for Methamphetamine, 3,4-Methylene-dioxymethamphetamine, andTheir Metabolites in Urine 227

      9.3.2 Newborn Screening for Phenylketonuria 227

      9.3.3 DART-MS Analysis of Skin Metabolome Changes in Ultraviolet B-Induced Mice 228

      9.3.4 Application in Detection of Breast Cancer 231

      9.3.5 Transmission Mode DART-MS for Fast Untargeted Metabolic Fingerprinting 232

      9.3.6 Applications of Confined DART Ion Source for Online In vivo Analysis of Human Breath 233

      9.3.6.1 Real-Time Analysis of Exhaled Breath 234

      9.3.6.2 Real-Time Monitoring of Oral Anesthetic Drug 235

      9.4 Challenges and Limitations 236

      9.5 Recent Advancements 237

      References 238

      10 DART-MS Applications in Pharmaceuticals 241
      Karina G. Putri, Qianwen Wu, and Young P. Jang

      10.1 Pharmaceutical Analysis 241

      10.2 Quality Assurance 243

      10.3 Illegal Active Pharmaceutical Ingredients and Counterfeit Drugs 244

      10.4 Drug Development 247

      References 251

      11 Application of DART-MS in Natural Phytochemical Research 255
      Vikas Bajpai, Awantika Singh, Brijesh Kumar, and Kunnath P. Madhusudanan

      11.1 Introduction 255

      11.2 Direct Analysis in Real Time (DART)Mass Spectrometry 256

      11.3 DART-MS Parameter Optimization for Phytochemical Analysis 256

      11.4 Applications of DART-MS in Phytochemical Research 257

      11.4.1 Qualitative Phytochemical Analysis 257

      11.4.2 Cell Culture Analysis 261

      11.4.3 Analysis of Volatiles 261

      11.4.4 Species Identification 262

      11.4.5 Metabolic Profiling and Multivariate Analysis 263

      11.4.6 Quantitative Analysis 274

      11.5 Hyphenated DART-MS Techniques for Phytochemical Analysis 276

      11.5.1 GC and HPLC-DART-MS 276

      11.5.2 TLC/HPTLC-DART-MS 276

      11.5.3 Capillary Electrophoresis-DART MS 277

      11.5.4 DART-IMS-MS 277

      11.5.5 Other Coupling Techniques 277

      11.6 Improving Sensitivity of DART-MS for Phytochemical Analysis 278

      11.6.1 Solvents and Gases 278

      11.6.2 Matrix Suppression 279

      11.7 DART -MS as Process Analytical Technology 279

      11.8 Future Perspective 280

      References 280

      12 Miscellaneous Applications of DART-MS 291
      Yoshihito Okada

      12.1 Introduction 291

      12.2 Usefulness of Negative-IonMode 292

      12.3 Application to Archeology and Conservation 293

      12.4 Application by Using TLC 293

      12.5 Application to Low Volatility, ChemicalWarfare, and Homeland Security 294

      12.6 Pheromone Profiles from Live Animals in Parallel with Behavior 295

      12.7 Application to Distinction of Plants with Similarity 296

      12.8 Application to Space 298

      12.9 Application to Bituminous Coals 298

      12.10 Application to Detection of Nicotine 298

      12.11 Other Potential Applications of DART-MS 299

      12.11.1 Instantaneous Screening for Counterfeit Drugs with No Sample Preparation [26-1] 299

      12.11.2 Direct Analysis of Drugs in Pills and Capsules with No Sample Preparation [26-2] 300

      12.11.3 Detection of Lycopene in Tomato Skin [26-3] 300

      12.11.4 Distribution of Capsaicin in Chili Peppers [26-4] 302

      12.11.5 Detection of Unstable Compound Released by Chopped Chives [26-5] 302

      12.11.6 Rapid Detection of Fungicide in Orange Peel [26-6] 304

      12.11.7 "Laundry Detective": Identification of a Stain [26-7] 304

      12.11.8 Detection of the Peroxide Explosives TATP and HMTD [26-8] 306

      12.11.9 Instantaneous Detection of Explosives on Clothing [26-9] 306

      12.11.10 Rapid Detection and Exact Mass Measurements of Trace Components in a Herbicide [26-10] 308

      12.11.11 Rapid Analysis of p-Phenylenediamine Antioxidants in Rubber [26-11] 308

      Acknowledgment 309

      References 309

      13 Inherent Limitations and Prospects of DART-MS 313
      Tim T. Häbe, Matthias Nitsch, and Gertrud E. Morlock

      13.1 Aspects of Inherent Limitations of DART-MS 313

      13.1.1 Gas Settings 314

      13.1.1.1 Type of Gas 314

      13.1.1.2 Gas Temperature 314

      13.1.1.3 Gas Flow Rate 317

      13.1.2 Voltage of Electrodes 317

      13.1.3 Sample Introduction and Positioning 318

      13.1.4 Detection System and Mass Range 318

      13.1.5 Matrix Effects and the Need for Chromatography 319

      13.1.6 Buffer and Salt Effects 321

      13.1.7 Sample Carrier and Solvent 322

      13.1.8 Humidity Effects 322

      13.1.9 Use of Isotopically Labeled Standards 322

      13.1.10 Dopant and Derivatization 323

      13.2 DART versus Other Ambient Ion Sources 324

      13.3 Prospects of DART-MS 326

      13.3.1 Automation and Miniaturized DART-MS 326

      13.3.2 Sample Preparation, Preconcentration, and Introduction 327

      13.3.3 Ion Focusing and Flexible Ion Transportation 327

      13.3.4 Quantitative Surface Scanning and Imaging by DART-MS 328

      13.3.5 Hyphenation of Effect-Directed Analysis and DART-MS 331

      13.3.6 Thermal Separations by Temperature Gradients 331

      13.3.7 Aerosol, in situ and in stillo Chemical Reaction and Kinetic Monitoring 332

      13.3.8 High Resolution and Data Analysis 332

      13.4 Concluding Remarks 333

      References 333

      Index 345

      Recently viewed products

      © 2026 Book Curl

        • American Express
        • Apple Pay
        • Diners Club
        • Discover
        • Google Pay
        • Maestro
        • Mastercard
        • PayPal
        • Shop Pay
        • Union Pay
        • Visa

        Login

        Forgot your password?

        Don't have an account yet?
        Create account